Comay Controller

InteliLiteNTMRS series is a single-engine generator set manually or self-starting integrated monitoring, protection controller, used a total of 3 MRS Model: 3,10, 16; 16 can be connected with J1939 EFI, automatic or manual start / stop, simple button operation, with LED and LCD triple the number of available modules panel keys or a computer to change the generator three-phase protection, generators measuring (50 / 60Hz): U1-U3, I1-I3, Hz, KVA, KW, KVAr, kWh; of imported inputs and outputs can be configured with fault history meter record (16).

A, ATS Function Controller Model

InteliLiteNTAMF series is a single generator set as a backup power source used to meet most of the mains failure detection system requirements, including modem connection, the user can change the configuration (via password) integrated monitoring and protection and generator sets, (2) AMF Type: 20,25. J1939 can be connected with EFI Machine (25 type) * Automatic or manual start / stop button easy operation, with LED and LCD triple the number of available modules panel keys or a computer to change, mains measurement (50 / 60Hz): U1 -U3, Hz generator three-phase protection, generators measuring (50 / 60Hz): U1-U3, I1-I3, Hz, KVA, KW, KVAr, kWh of imported inputs and outputs can be configured with fault history meter record (25 type ) *.

Second, and machine function controller model

InteliCompactNT (IC-NT) type is single and parallel units of the latest integrated monitoring and protection module .. Operation, configuration simple, built-in auto synchronizer, active and reactive load sharer. It can be on the same network so that 32 units in parallel; mains failure from the start, long-term parallel operation, and can connect using J1939, Modbus and ECU Some proprietary protocols, alarm with text display, base load in multiple parallel systems optimize the number of operating units , input and output can be configured imports, faulty count recorded history.

Three, MainsCompact NT

MainsCompactNT is to reach the controller 31 units operating in parallel with the city network. Mains measurement: U, I, Hz, kW, kVAr, kVA, PF, kWh, kVArh busbar measurement: U, I, HZ with built-Mains protection monitoring mains failure, can be connected with or without the system installed MGCB According mains input or output load power consumption adjustment, a faulty count recorded history.

Four, InteliGen NT

InteliGenNT single station and city network or parallel units by the controller, mains failure from the start, long-term parallel operation, standby and parallel controllers can be connected using the J1939, Modbus and a number of special agreements permit the choice of suitable application mode ECU. Alarm with text display base load, input / output peripherals power control InteliGenNT EE designed with EFI unit optimized to run multiple parallel system, the number of unit input / output can be configured special version, fault history of 500, and a PLC programming.

Fifth, the generator set controller

1, InteliSys NT

InteliSysNT (IS-NT) is single and multiple backup generators and parallel scalable controller. Particularly suitable for thermoelectric CISS and other complex systems. Can be installed separately from the display is more conducive to install, you can use a variety of expansion modules to meet customer application needs, support thermoelectric CISS (prepared programmable PID control loop and other PLC functions are available) can be connected using the J1939, Modbus, and some ECU proprietary protocol, the alarm text display to base load, input / output and peripheral power control of multiple parallel system to optimize operation of the unit number of inputs and outputs can be configured, fault history up to 1000.

2, InteliMains NT

InteliMainsNT (IM-NT) is to reach 31 Mains measurement: U, I, Hz, kW, kVAr, kVA, PF, kWh, each unit with the city network parallel operation of the controller. kVAhr IM-NT can be set to the tie-switch synchronous control busbar measurement: switch U, I, Hz around the unit between groups combined points built mains failure detection contact switch mode selectable full or partial control MCB can input based on electricity or electricity generation capacity adjustment fault history.

Sixth, the engine controller

The InteliDrive Lite is integrated engine monitoring and protection module. Suitable for diesel and gas engines. This series controllers have different versions to provide different land use and (non Chuanjian request) marine application engine control, monitoring, protection speed measurement: J1939 data read by sensors or six pairs of binary input / output, 3-way analog Input / output can be configured setpoint can be set to change the lock on the panel or PC.